| Dental lab items |
| Acryliser |
Large: for 16 flasks. Small: for 8 flasks
Micro computerized control with Large LCD screen for messages & values and
With Unique
Power failure memory:
auto re-starts process on power resumption.
Versatility:
permits stop & edit at any time during process on
User friendly:
single key press starts & completes process on its own * supervision not
required * displays “process over“ message on completion * blinking light
draws user attention for message on screen * flashes help messages on
screen to guide user
User programmable time - temp cycle.
Protection from tampering of set parameters: Password incorporated
Self diagnostics software: displays fault condition on screen making repairs easy.
Robust unit: fully stainless steel body.
Safety: power configured in cut-off mode in its natural steady state of rest |
|
 |
|
| Specifications: |
 |
Construction |
|
Stainless Steel |
 |
Sizes |
|
18X18X18” – LARGE , 16x12x12” – SMALL |
 |
Water Filling |
|
Manual |
 |
Power Rating – Heater |
|
3000 / 2000 Watts for 2 sizes resp. |
 |
Control |
|
Less than 50 Watts |
 |
Operating Voltage |
|
230 Volts +/- 10%, 50 Hz, 1Phase |
 |
Controller Type |
|
Micro Computerized with LCD Display |
 |
Display Type |
|
4 x 20 Liquid Crystal Display (4 rows x 20 characters) |
 |
No. of flasks accommodated |
|
About 16 / 8 for 2 sizes resp. |
 |
Protection |
|
Password Protection against un-authorized tampering |
 |
Power Failure Memory |
|
Built-in |
 |
Curing Process |
|
2 Time – Temp cycles with Auto Changeover |
 |
Default Cycle |
|
65deg. C for 45 mins; 95 Deg.C for 60 mins |
 |
Set Temperature / Time |
|
By various keys on keyboard. |
 |
Temp / Time Set Range |
|
0 to 99 Deg C. / 0 to 9:59 (H:MM) |
 |
User Cycles |
|
Programmable through front panel key switches |
 |
Alert / Message Indication |
|
Blinking Light with message on screen |
 |
Screen Display |
|
1) Help Messages,
2) Error Messages,
3) Set and Actual Temp,
4) Set and Balance Time,
5) Pre Cure / Curing Cycle Running,
6) Temp Rise / Fall,
7) Temp Bar Graph,
8) Process Over Message 9) Heater Status |
 |
Process End |
|
Auto OFF with Message and Alerts |
|
| POWER FAILURE MEMORY – HOW IT WORKS? |
| Once the “Run” key is pressed, the process starts and micro-controller continuously monitors the process parameters and saves them in internal memory. At Power Failure these process parameters are stored in Memory provided on board. This memory is non-volatile and can be retained for a long period.
On resumption of power, the controller restarts and retrieves the temperature value at power failure and compares it with actual value on power resumption. If the drop in temperature is more than 10% of the value at power failure, then the processor re-starts the process from beginning and if f the drop in temperature is less than 10% of the stored value, then the process resumes from where it stopped at power failure.
This is done automatically. |
| WHY PASSWORD? |
| Password is required only to edit process parameters like set temperature time. Password is not required to Run the Process with previously set values.
This facilitates the control of Supervisor or H.O.D over process parameters set values and permits the Junior staff / student to run the process without need of presence to Supervisor / H. O. D. |
| WHAT IF PASSWORD FORGOTEN? |
If the user has forgotten Password, then the default Password can be loaded through Key Switch on the right face of the control panel.
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE |
| |
|
| AUTOCLAVE - PROGRAMMABLE - FRONT LOADING |
Micro computerised control with LCD screen for messages and
With Unique
Power failure memory :
Auto re-starts process on power resumption.
User friendly:
single key press starts & completes process on its own * supervision
not required * displays “process over” message on completion * blinking
light for user attention on message on screen * help messages on screen
Protection from tampering of set parameters: Password incorporated
User programmable :
Temp: 121 to 135 deg. C, Time: 15 to 59 mins
Safety valve. Pressure gauge. Drum size: 6” x 6”
Automatic release of steam on completion of claving cycle
Front Loading type construction for ease of operation
Robust construction:
Stainless steel claving chamber with M. S. Powder Coated Control body.
Safety: process power configured in cut-off mde in its steady state of rest
Self Diagnostic Software identifies process faults and displays on screen e.g.: Sensor error, Check Water Level, Heating not progressing etc etc
Versatility:
Permits stop & edit at any time during process run Provision to Run Wet Cycle alone or Wet and Dry Cycle. |
|
 |
|
| Specifications: |
|
| POWER FAILURE MEMORY – HOW IT WORKS? |
| Once the “Run” key is pressed, the process starts and micro-controller continuously monitors the process parameters and saves them in internal memory. At Power Failure these process parameters are stored in Memory provided on board. This memory is non-volatile and can be retained for a long period.
On resumption of power, the controller restarts and retrieves the temperature value at power failure and compares it with actual value on power resumption. If the drop in temperature is more than 10% of the value at power failure, then the processor re-starts the process from beginning and if f the drop in temperature is less than 10% of the stored value, then the process resumes from where it stopped at power failure. |
| WHY PASSWORD? |
Password is required only to edit process parameters like set temperature time. Password is not required to Run the Process with previously set values.
This facilitates the control of Supervisor or H.O.D over process parameters set values and permits the Junior staff / student to run the process without need of presence to Supervisor / H. O. D. |
| WHAT IF PASSWORD FORGOTEN? |
If the user has forgotten Password, then the default Password can be loaded through Key Switch on the right face of the control panel.
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE |
| |
|
| Auto Clave - Std |
Electrically operated.
Safety valve for release of steam pressure beyond 16 psi
Pressure gauge
Fully stainless steel body
Suitable for Drum Size: 9” x 9”
|
|
 |
|
| Specifications: |
|
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
|
|
| Burn Furnace - Programable |
STD MUFFLE: 4” X 4” X 8”. LARGE MUFFLE: 5” X 5” X 7”
Micro computerised control with Large LCD screen for messages & values and
With Unique
Power failure memory: auto re-starts process on power resumption.
Versatility: permits stop & edit at any time during process on
User friendly:
single key press starts & completes process on its own * supervision not
required * displays “process over” message on completion * blinking light
draws user attention to messages on screen.
5 programmes each with 3 user programmable steps
Each step programmable for: hold temperature * hold time * heating rate
Linear Heating Rate programmable for range of 10 Degrees C (from 0 – 9 Degree C)
Hold Time Programmable for 100 Minutes (Optional 100 Hours) (from 0 to 99.9)
Maximum temperature for 1000 Deg. C range (0 to 999 degree C)
Safety: power configured in cut-off mode in its natural steady state of rest
M.S. Powder coated body. |
|
 |
|
| Specifications: |
|
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
|
| POWER FAILURE MEMORY – HOW IT WORKS? |
| Once the “Run” key is pressed, the process starts and micro-controller continuously monitors the process parameters and saves them in internal memory. At Power Failure these process parameters are stored in Memory provided on board. This memory is non-volatile and can be retained for a long period.
On resumption of power, the controller restarts and retrieves the temperature value at power failure and compares it with actual value on power resumption. If the drop in temperature is more than 10% of the value at power failure, then the processor re-starts the process from beginning and if f the drop in temperature is less than 10% of the stored value, then the process resumes from where it stopped at power failure. |
| WHY PASSWORD? |
Password is required only to edit process parameters like set temperature time. Password is not required to Run the Process with previously set values.
This facilitates the control of Supervisor or H.O.D over process parameters set values and permits the Junior staff / student to run the process without need of presence to Supervisor / H. O. D. |
| WHAT IF PASSWORD FORGOTEN? |
If the user has forgotten Password, then the default Password can be loaded through Key Switch on the right face of the control panel.
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE |
| |
|
| CAST DUPLICATOR |
3 kg capacity – ideal for the day’s work
Computerised control of process including heating, cooling, stirring, and timing.
Large LCD screen for digital display of messages and process status
User friendly :
single key press starts & completes process on its own * supervision not required *
displays “process over“ message on completion * blinking light draws user attention
for message on screen * flashes help messages on screen to guide user
User programmable temperature and time
Stirrer on/off facilitated by key switch
Prepares & maintains duplicating gel in ready to use form for indefinite period.
Low power uniform heating from all sides prevents burning of gel
Low speed stirrer ensures homogenous mixing without splashing
Convenient outlet for ease of dispensing
Ultra low power continuous heating of outlet ensures gel does not solidify in outlet system
Protection from tampering of set parameters: Password incorporated
Power failure memory :
auto re-starts process on power resumption.
Robust unit:
fully stainless steel body.
Safety:
power configured in cut-off mode in its natural steady state of rest
Versatility:
permits stop & edit at any time during process on |
|
 |
|
| Specifications: |
|
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
|
| POWER FAILURE MEMORY – HOW IT WORKS? |
| Once the “Run” key is pressed, the process starts and micro-controller continuously monitors the process parameters and saves them in internal memory. At Power Failure these process parameters are stored in Memory provided on board. This memory is non-volatile and can be retained for a long period.
On resumption of power, the controller restarts and retrieves the temperature value at power failure and compares it with actual value on power resumption. If the drop in temperature is more than 10% of the value at power failure, then the processor re-starts the process from beginning and if f the drop in temperature is less than 10% of the stored value, then the process resumes from where it stopped at power failure.
This is done automatically.
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE |
| |
|
| Dental Lathe - HD |
|
| Dental Lathe - Std |
|
| De-Waxing Unit |
Accomodates 8 flasks in a layered manner facilitating easy removal and addition of flask
Micro computerized control with LCD screen for messages & values and
With Unique
Power failure memory:
auto re-starts process on power resumption.
Versatility:
permits stop & edit at any time during process on
User friendly:
single key press starts & completes process on its own * supervision not
required * displays “process over“ message on completion * blinking
light draws user attention for message on screen * flashes help messages
on screen to guide user
User programmable time - temp cycle.
Protection from tampering of set parameters: Password incorporated
Self diagnostics software: displays fault condition on screen making repairs easy.
Robust unit:
fully stainless steel body.
Safety:
power configured in cut-off mode in its natural steady state of rest
|
|
 |
|
| Specifications: |
|
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
|
| POWER FAILURE MEMORY – HOW IT WORKS? |
| Once the “Run” key is pressed, the process starts and micro-controller continuously monitors the process parameters and saves them in internal memory. At Power Failure these process parameters are stored in Memory provided on board. This memory is non-volatile and can be retained for a long period.
On resumption of power, the controller restarts and retrieves the temperature value at power failure and compares it with actual value on power resumption. If the drop in temperature is more than 10% of the value at power failure, then the processor re-starts the process from beginning and if f the drop in temperature is less than 10% of the stored value, then the process resumes from where it stopped at power failure.
This is done automatically.
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE |
| |
|
| Electric Carver |
Electronic control circuit ensures steady heating at set temperature
Continuous uniform heating to enable concentration on pattern making
Ultra light weight carving pencil reduces fatigue of the fingers.
Temperature control from 60 to 160 deg. Centigrade. Marking on dial
Fast heating
DUAL CHANNEL WITH INDEPENDENT TEMPERATURE CONTROLS
2 TECHNICIANS CAN WORK SIMULTANEOUSLY.
Last But Not Least
Ultra low power consumption resulting in Ultra low operating cost.
Approximately 100 Hours of continuous use of both channels simultaneously at maximum temperature results in consumption of
ONLY ONE UNIT OF ELECTRICITY |
|
 |
|
| Specifications: |
|
| DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE |
| |
|
| Electro Polisher Anodiser |
Ideal for polishing of dental alloy steel - braces and cast partials to provide surface with bright glossy and durable luster.
Electronic control circuit
Continuous protection against accidental short circuit and over current
Automatic Current Control based on electrolyte and objects, to regulate polishing rate
Continuous Power Setting through Knob over the Polishing Range.
Large digital display to see the polishing rate
|
|
 |
|
| Specifications: |
|
OPTIONAL:
|
ENHANCED POWER SETTING RANGE TO 10 – 12 Amps.
MAX. POWER CONSUMPTION SHALL INCREASE TO 350 WATTS.
|
RECOMMENDED
|
Standard Power Range of 0 to 5 Amps is most ideal for dental applications.
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE |
| |
|
| Hot Air Steriliser_Dry Heat Oven |
Accomodates 8 flasks in a layered manner facilitating easy removal and addition of flask
Micro computerized control with LCD screen for messages & values and
With Unique
Power failure memory:
auto re-starts process on power resumption.
Versatility:
permits stop & edit at any time during process on
User friendly:
single key press starts & completes process on its own * supervision not
required * displays “process over“ message on completion * blinking
light draws user attention for message on screen * flashes help messages
on screen to guide user
User programmable time - temp cycle.
Protection from tampering of set parameters: Password incorporated
Self diagnostics software: displays fault condition on screen making repairs easy.
Robust unit:
stainless steel sterilising chamber and M.S. Powder Coated body.
Safety:
power configured in cut-off mode in its natural steady state of rest
|
|
 |
|
| Specifications: |
|
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
|
| POWER FAILURE MEMORY – HOW IT WORKS? |
| Once the “Run” key is pressed, the process starts and micro-controller continuously monitors the process parameters and saves them in internal memory. At Power Failure these process parameters are stored in Memory provided on board. This memory is non-volatile and can be retained for a long period.
On resumption of power, the controller restarts and retrieves the temperature value at power failure and compares it with actual value on power resumption. If the drop in temperature is more than 10% of the value at power failure, then the processor re-starts the process from beginning and if f the drop in temperature is less than 10% of the stored value, then the process resumes from where it stopped at power failure.
This is done automatically.
|
| WHY PASSWORD? |
Password is required only to edit process parameters like set temperature time. Password is not required to Run the Process with previously set values.
This facilitates the control of Supervisor or H.O.D over process parameters set values and permits the Junior staff / student to run the process without need of presence to Supervisor / H. O. D.
|
| WHAT IF PASSWORD FORGOTEN? |
If the user has forgotten Password, then the default Password can be loaded through Key Switch on the right face of the control panel.
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE |
| |
|
| Hydraulic Press |
Capacity 3 tons
Perfectly packs the flask after filling acrylic
Exerts uniform pressure throughout the surface
Hydraulic gauge indicates pressure in tons
Ease of operation
Simple release mechanism
|
|
 |
|
| Specifications: |
|
| DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
|
| |
|
| Model Trimmer |
High Speed Heavy Duty Motor
Front Face Operation
Perfect ergonomics for ease of use
Option for Coarse or Fine Grinding Disc |
|
 |
|
| Specifications: |
|
| DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE |
| |
|
| Pindex Laser System |
Ideal for split model technique
Bright laser light for accurate drill point setting
User adjustable laser positioning system
High speed drill motor
Large platform
Sturdy body
|
|
 |
|
| Specifications: |
|
| DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE |
| |
|
| Plaster Dispenser |
10 kg capacity
Auto operation at the flick of a switch. No pulling of lever required
Dispensing start / stop controlled by toggle switch
Flexible mounting: wall or table
|
|
 |
|
| Specifications: |
|
| DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE |
| |
|
| Pre Heating Furnace |
Max temp: 500 deg. C.
Muffle size: 4 x 4x 8”
Digital controller plus indicator
Compact size
|
|
 |
|
| Specifications: |
|
| DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE |
| |
|
| Pressure Pot - Cold Cure |
Indispensable unit for Porosity Free Polymerisation of Self Cure Resin
Time saving. Performs process very fast at the press of a button.
Cost saving. 10 models can be cured at a time.
Stainless steel curing chamber with Safety Valve and Pressure Gauge
Pressure cooker construction for convenient loading and unloading of models.
|
|
 |
|
| Specifications: |
|
| DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE |
| |
|
| Pressure Pot - Heat Cure |
Indispensable unit for Porosity Free Polymerization of Heat Cure Resin in crowns and bridges
Time saving. Performs process very fast at the press of a button.
Micro controller based fully automatic unit
Big screen for display of messages and menu
Cost saving. 10 models can be cured at a time.
Stainless steel curing chamber with Safety Valve and Pressure Gauge
Pressure cooker construction for convenient loading and unloading of models.
|
|
 |
|
| Specifications: |
|
| DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE |
| |
|
| Sand Blaster - Recycle |
Large blasting chamber with light
Two blasting nozzles :
Hand pencil for micro (250 microns) sand for ceramic work
Fixed nozzle for macro (400 microns) sand for white metal work
Macro blasting with fixed nozzle recycles sand utilizing full abrasive strength.
Micro blasting done with hand held carbide nozzle.
Micro sand is filled in a jar outside chamber. Used sand falls within chamber which is once again recycled by macro blasting thereby allowing maximum utilization of the abrasive strength.
Hand switch to change blasting mode: micro to macro and vice versa.
Provision for connecting dust extractor
Foot Switch operations.
Operating Pressure 3 to 3.5 bars with pressure zone marked on the gauge.
OPTIONAL
Filter module for protection from dust (dust suction). |
|
 |
|
| Specifications: |
|
| DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE |
| |
|
| Suction Lathe |
Micro computerised operation and control.
Low noise motorised suction * Low power consumption.
Bottle inside equipment body,
Auto Start / Stop: Suction starts on lifting the tip from holder. Stops on replacing.
Auto Drain: Automatically drains off when bottle full.
|
|
 |
|
| Specifications: |
|
| DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE |
| |
|
| Ultrasonic Cleaner |
Specially made for dentists with 1.5 ltr tank capacity. Tanks with higher capacities can be made on request.
Fully stainless steel tank enclosed in durable stainless steel water resistant housing
High power balancing circuit with ideally placed vibrators for efficient cleaning
Built – in heater with thermal cut-off and on/off switch to regulate heating
Microprocessor based count down timer programmable for upto 60 mins
Instant Cleaning Power released on start up.
Meshed tray for maximum unobstructed transfer of cleaning power to the jobs to be cleaned
Dimensions designed to optimally accommodate all hand instruments |
|
 |
|
| Specifications: |
|
| DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE |
| |
|
| Vacuum Mixer - Programmable |
Micro computerized control with LCD screen for messages and process result and
With Unique
Single Run Mode for trial of new investment / plaster
5 programmes
3 levels in each programme: pre-mix, mix and post-mix time
Fully automatic
Hands free operations
Edit and save / run facility
Vacuum Gauge for Vacuum Display |
|
 |
|
| Specifications: |
|
| DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE |
| |
|
| Vibrator - Heavy Duty |
Heavy Duty
Large Rubber Platform Easy to Clean
Vibration absorbing base
Sturdy Construction |
|
 |
|
| Specifications: |
 |
Construction |
|
M. S. Powder Coated |
 |
Operating Voltage |
|
230 V AC, 50 – 60 Hz, 1 Phase |
 |
Platform |
|
Large Rubber Platform |
| |
|
|
|
|
| DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE |
| |
|
| |