Email Us: info@amanint.com
Follow us on twitter
Products
Dental lab items
Acryliser
Large: for 16 flasks. Small: for 8 flasks
Micro computerized control with Large LCD screen for messages & values and
With Unique
Power failure memory:
auto re-starts process on power resumption.
Versatility:
permits stop & edit at any time during process on
User friendly:
single key press starts & completes process on its own * supervision not
required * displays “process over“ message on completion * blinking light
draws user attention for message on screen * flashes help messages on
screen to guide user
User programmable time - temp cycle.
Protection from tampering of set parameters: Password incorporated
Self diagnostics software: displays fault condition on screen making repairs easy.
Robust unit: fully stainless steel body.
Safety: power configured in cut-off mode in its natural steady state of rest
 
Specifications:
Construction  

Stainless Steel

Sizes   18X18X18” – LARGE , 16x12x12” – SMALL
Water Filling       Manual
Power Rating – Heater   3000 / 2000 Watts for 2 sizes resp.
Control   Less than 50 Watts
Operating Voltage   230 Volts +/- 10%, 50 Hz, 1Phase
Controller Type   Micro Computerized with LCD Display
Display Type   4 x 20 Liquid Crystal Display (4 rows x 20 characters)
No. of flasks accommodated      About 16 / 8 for 2 sizes resp.
Protection           Password Protection against un-authorized tampering
Power Failure Memory   Built-in
Curing Process   2 Time – Temp cycles with Auto Changeover
Default Cycle  

65deg. C for 45 mins; 95 Deg.C for 60 mins

Set Temperature / Time             

By various keys on keyboard.

Temp / Time Set Range                  0 to 99 Deg C. / 0 to 9:59 (H:MM)
User Cycles  

Programmable through front panel key switches

Alert / Message Indication         

Blinking Light with message on screen

Screen Display  

1) Help Messages,
2) Error Messages,
3) Set and Actual Temp,
4) Set and Balance Time,
5) Pre Cure / Curing Cycle Running,
6) Temp Rise / Fall,
7) Temp Bar Graph,
8) Process Over Message 9) Heater Status

Process End   Auto OFF with Message and Alerts
POWER FAILURE MEMORY – HOW IT WORKS?
Once the “Run” key is pressed, the process starts and micro-controller continuously monitors the process parameters and saves them in internal memory. At Power Failure these process parameters are stored in Memory provided on board. This memory is non-volatile and can be retained for a long period.

On resumption of power, the controller restarts and retrieves the temperature value at power failure and compares it with actual value on power resumption. If the drop in temperature is more than 10% of the value at power failure, then the processor re-starts the process from beginning and if f the drop in temperature is less than 10% of the stored value, then the process resumes from where it stopped at power failure.
This is done automatically.

WHY PASSWORD?
Password is required only to edit process parameters like set temperature time. Password is not required to Run the Process with previously set values.

This facilitates the control of Supervisor or H.O.D over process parameters set values and permits the Junior staff / student to run the process without need of presence to Supervisor / H. O. D.

WHAT IF PASSWORD FORGOTEN?

If the user has forgotten Password, then the default Password can be loaded through Key Switch on the right face of the control panel.

DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE

 
AUTOCLAVE - PROGRAMMABLE - FRONT LOADING
Micro computerised control with LCD screen for messages and
With Unique
Power failure memory :
Auto re-starts process on power resumption.
User friendly:
single key press starts & completes process on its own * supervision
not required * displays “process over” message on completion * blinking
light for user attention on message on screen * help messages on screen
Protection from tampering of set parameters: Password incorporated
User programmable :
Temp: 121 to 135 deg. C, Time: 15 to 59 mins
Safety valve. Pressure gauge. Drum size: 6” x 6”
Automatic release of steam on completion of claving cycle
Front Loading type construction for ease of operation
Robust construction:
Stainless steel claving chamber with M. S. Powder Coated Control body.
Safety: process power configured in cut-off mde in its steady state of rest
Self Diagnostic Software identifies process faults and displays on screen e.g.: Sensor error, Check Water Level, Heating not progressing etc etc
Versatility:
Permits stop & edit at any time during process run Provision to Run Wet Cycle alone or Wet and Dry Cycle.
 
Specifications:
Power Rating – Heater        

2000 Watts

Control System                      Less than 50 Watts
Water Filling   Manual
Operating Voltage          230 Volts +/- 10%, 50 Hz, 1Phase
Control Type                        Micro-computerised control with LCD display.
Protection           Password Protection against un-authorized tampering
Memory  

Stores the process condition at power failure and continues on Power resumption.

Alerts Indication                   By Blinking Light.
Temp Set Range                   121 to 135 Degree Centigrade
Set Time Range                    15 to 59 Minutes
Display   2 x 16 Liquid Crystal Display  (2 Rows x 16 Charatcers)
Indication on Display          

Set/Actual Temp in Deg. Centigrade *  Set Time in MM*
 Process Alerts *  Process Over

POWER FAILURE MEMORY – HOW IT WORKS?
Once the “Run” key is pressed, the process starts and micro-controller continuously monitors the process parameters and saves them in internal memory. At Power Failure these process parameters are stored in Memory provided on board. This memory is non-volatile and can be retained for a long period.

On resumption of power, the controller restarts and retrieves the temperature value at power failure and compares it with actual value on power resumption. If the drop in temperature is more than 10% of the value at power failure, then the processor re-starts the process from beginning and if f the drop in temperature is less than 10% of the stored value, then the process resumes from where it stopped at power failure.

WHY PASSWORD?

Password is required only to edit process parameters like set temperature time. Password is not required to Run the Process with previously set values.

This facilitates the control of Supervisor or H.O.D over process parameters set values and permits the Junior staff / student to run the process without need of presence to Supervisor / H. O. D.

WHAT IF PASSWORD FORGOTEN?

If the user has forgotten Password, then the default Password can be loaded through Key Switch on the right face of the control panel.

DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE

 
Auto Clave - Std
Electrically operated.
Safety valve for release of steam pressure beyond 16 psi
Pressure gauge
Fully stainless steel body
Suitable for Drum Size: 9” x 9”


 
Specifications:
Construction         

Fully Stainless Steel

Power Rating – Heater         1000 Watts
Pressure Control                   By release of steam
Operation   Manual
Operating Voltage   230 Volts +/- 10%, 50 Hz, 1Phase
Pressure Indication               By Pressure Gauge.
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
Burn Furnace - Programable
STD MUFFLE: 4” X 4” X 8”. LARGE MUFFLE: 5” X 5” X 7”
Micro computerised control with Large LCD screen for messages & values and
With Unique
Power failure memory: auto re-starts process on power resumption.
Versatility: permits stop & edit at any time during process on
User friendly:
single key press starts & completes process on its own * supervision not
required * displays “process over” message on completion * blinking light
draws user attention to messages on screen.
5 programmes each with 3 user programmable steps
Each step programmable for: hold temperature * hold time * heating rate
Linear Heating Rate programmable for range of 10 Degrees C (from 0 – 9 Degree C)
Hold Time Programmable for 100 Minutes (Optional 100 Hours) (from 0 to 99.9)
Maximum temperature for 1000 Deg. C range (0 to 999 degree C)
Safety: power configured in cut-off mode in its natural steady state of rest
M.S. Powder coated body.
 
Specifications:
Size     

400 (L) x 370 (D) x 490 (H) mm

Weight   Approx. 25 Kg
Operating Voltage                 230 Volts AC, 50 Hz, 1Phase, Stabilised
Power Consumption – Std / Large              1700 / 3200 Watts
Control Power  

Less than 50 Watts

Max. Temp Withstanding.                 

1000 Deg. Centigrade continuous

Programming   By Front Panel Key Switches 
Soak Temperature                            3 points can be set from 0 to 999 Deg. Centigrade
Soak Time  

3 points can be set from 0 to 99.9 Minutes

Rate of Rise of Temp                      0 to 9 Deg. C/min
Indication   4 Line 20 characters Liquid Crystal Display Screen
Other Feature   Power Failure Memory
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
POWER FAILURE MEMORY – HOW IT WORKS?
Once the “Run” key is pressed, the process starts and micro-controller continuously monitors the process parameters and saves them in internal memory. At Power Failure these process parameters are stored in Memory provided on board. This memory is non-volatile and can be retained for a long period.

On resumption of power, the controller restarts and retrieves the temperature value at power failure and compares it with actual value on power resumption. If the drop in temperature is more than 10% of the value at power failure, then the processor re-starts the process from beginning and if f the drop in temperature is less than 10% of the stored value, then the process resumes from where it stopped at power failure.

WHY PASSWORD?

Password is required only to edit process parameters like set temperature time. Password is not required to Run the Process with previously set values.

This facilitates the control of Supervisor or H.O.D over process parameters set values and permits the Junior staff / student to run the process without need of presence to Supervisor / H. O. D.

WHAT IF PASSWORD FORGOTEN?

If the user has forgotten Password, then the default Password can be loaded through Key Switch on the right face of the control panel.

DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE

 
CAST DUPLICATOR
3 kg capacity – ideal for the day’s work
Computerised control of process including heating, cooling, stirring, and timing.
Large LCD screen for digital display of messages and process status
User friendly :
single key press starts & completes process on its own * supervision not required *
displays “process over“ message on completion * blinking light draws user attention
for message on screen * flashes help messages on screen to guide user
User programmable temperature and time Stirrer on/off facilitated by key switch
Prepares & maintains duplicating gel in ready to use form for indefinite period.
Low power uniform heating from all sides prevents burning of gel Low speed stirrer ensures homogenous mixing without splashing Convenient outlet for ease of dispensing Ultra low power continuous heating of outlet ensures gel does not solidify in outlet system Protection from tampering of set parameters: Password incorporated
Power failure memory :
auto re-starts process on power resumption.
Robust unit:
fully stainless steel body.
Safety:
power configured in cut-off mode in its natural steady state of rest
Versatility:
permits stop & edit at any time during process on
 
Specifications:
Construction   Stainless Steel
Gel  Filling          Small pieces of Gel filled Manually
Capacity   3 Kg
Power Rating – Heater   250 Watts
Control   Less than 50 Watts
Operating Voltage   230 Volts +/- 10%, 50 Hz, 1Phase
Controller Type   Micro Computeised with LCD Display
Display Type  

2 x 16 Liquid Crystal Display (2 rows x 16 characters)

Protection           Password Protection against un-authorized tampering
Power Failure Memory  

Built-in

Process   2 Time – Temp cycles with Auto Changeover
Default Settings  

92deg. C for 5 mins; 55 Deg.C indefinitely

Set Temperature / Time  

By various keys on keyboard.

Temp / Time  Set Range                 

0 to 100 Deg C. / 0 to 9:59 (H:MM)

User Cycles   Programmable through front panel key switches
Alert / Message Indication  

Blinking Light with display on screen

Screen Display  

1) Help Messages
2) Error Messages
3) Set and Actual Temp
4) Set and Balance Time
5) Cycle Running
7) Process Over  Message                                                            

Process End   Auto OFF with Message
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
POWER FAILURE MEMORY – HOW IT WORKS?
Once the “Run” key is pressed, the process starts and micro-controller continuously monitors the process parameters and saves them in internal memory. At Power Failure these process parameters are stored in Memory provided on board. This memory is non-volatile and can be retained for a long period.

On resumption of power, the controller restarts and retrieves the temperature value at power failure and compares it with actual value on power resumption. If the drop in temperature is more than 10% of the value at power failure, then the processor re-starts the process from beginning and if f the drop in temperature is less than 10% of the stored value, then the process resumes from where it stopped at power failure.
This is done automatically.
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE

 
Dental Lathe - HD
   
Dental Lathe - Std
   
     
De-Waxing Unit

Accomodates 8 flasks in a layered manner facilitating easy removal and addition of flask Micro computerized control with LCD screen for messages & values and
With Unique
Power failure memory:
auto re-starts process on power resumption.
Versatility:
permits stop & edit at any time during process on
User friendly:
single key press starts & completes process on its own * supervision not
required * displays “process over“ message on completion * blinking
light draws user attention for message on screen * flashes help messages
on screen to guide user
User programmable time - temp cycle.
Protection from tampering of set parameters: Password incorporated
Self diagnostics software: displays fault condition on screen making repairs easy.
Robust unit:
fully stainless steel body.
Safety:
power configured in cut-off mode in its natural steady state of rest

 
Specifications:
Construction   Stainless Steel
Tank Sizes (Usable)                         16x12x 9” approx
Water Filling   Manual
Power Rating – Heater   2000 Watts
Control    Less than 50 Watts
Operating Voltage          230 Volts +/- 10%, 50 Hz, 1Phase
Controller Type              Micro Computerized with LCD Display
Display Type      2 x 16 Liquid Crystal Display (2 rows x 16 characters)
No. of flasks accommodated   8
Protection           Password Protection against un-authorized tampering
Power Failure Memory   Built-in
Process   Programmable Time – Temp cycles with Auto Off
Default Cycle  

92deg. C for 5 mins with Timer Programmed to “OFF “

Set Temperature / Time  

By various keys on keyboard.

Temp / Time  Set Range                 

0 to 99 Deg C. / 0 to 9:59 (H:MM)

User Cycles   Programmable through front panel key switches
Alert / Message Indication         

Blinking Light with display on screen

Screen Display  

1) Help Messages,
2) Error Messages,
3) Set and Actual Temp,
4) Set and Balance Time,
5) Pre Cure / Curing Cycle Running,
6) Temp Rise / Fall, 7) Temp Bar Graph,
8) Process Over  Message 9) Heater Status                                                      

Process End  

Auto OFF with Message and Alerts

DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
POWER FAILURE MEMORY – HOW IT WORKS?
Once the “Run” key is pressed, the process starts and micro-controller continuously monitors the process parameters and saves them in internal memory. At Power Failure these process parameters are stored in Memory provided on board. This memory is non-volatile and can be retained for a long period.

On resumption of power, the controller restarts and retrieves the temperature value at power failure and compares it with actual value on power resumption. If the drop in temperature is more than 10% of the value at power failure, then the processor re-starts the process from beginning and if f the drop in temperature is less than 10% of the stored value, then the process resumes from where it stopped at power failure.
This is done automatically.
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE

 
Electric Carver

Electronic control circuit ensures steady heating at set temperature
Continuous uniform heating to enable concentration on pattern making
Ultra light weight carving pencil reduces fatigue of the fingers.
Temperature control from 60 to 160 deg. Centigrade. Marking on dial
Fast heating
DUAL CHANNEL WITH INDEPENDENT TEMPERATURE CONTROLS
2 TECHNICIANS CAN WORK SIMULTANEOUSLY.

Last But Not Least
Ultra low power consumption resulting in Ultra low operating cost.

Approximately 100 Hours of continuous use of both channels simultaneously at maximum temperature results in consumption of

ONLY ONE UNIT OF ELECTRICITY

 
Specifications:
Construction: Controller   Light Weight M. S. Powder Coated
Carving Pencil          Moulded
Power Consumption                        5 Watts Max per channel at peak temp
Operating Voltage          230 Volts +/- 10%, 50 Hz, 1Phase
Controller Type  

Electronic

Operation  

Continuous indefinitely

       
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
 
Electro Polisher Anodiser

Ideal for polishing of dental alloy steel - braces and cast partials to provide surface with bright glossy and durable luster.

Electronic control circuit Continuous protection against accidental short circuit and over current Automatic Current Control based on electrolyte and objects, to regulate polishing rate Continuous Power Setting through Knob over the Polishing Range.

Large digital display to see the polishing rate

 
Specifications:
Construction  

M. S. Powder Coated

Operating Voltage                 230 Volts +/- 10%, 50 Hz, 1Phase
Control Type                                           Fully electronic
Protection    Short Circuit protection
Power Set Range                  

0  to 5 Amps continuously variable

Display  

3.5 Digit 0.5” height Bright LED Display

  Tank Capacity                       2 Litres
  Max. Power Consumption    150 Watts
       

OPTIONAL:

ENHANCED POWER SETTING RANGE TO 10 – 12 Amps.
MAX. POWER CONSUMPTION SHALL INCREASE TO 350 WATTS.


RECOMMENDED

Standard Power Range of 0 to 5 Amps is most ideal for dental applications.

DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE

 
Hot Air Steriliser_Dry Heat Oven

Accomodates 8 flasks in a layered manner facilitating easy removal and addition of flask Micro computerized control with LCD screen for messages & values and
With Unique
Power failure memory:
auto re-starts process on power resumption.
Versatility:
permits stop & edit at any time during process on
User friendly:
single key press starts & completes process on its own * supervision not
required * displays “process over“ message on completion * blinking
light draws user attention for message on screen * flashes help messages
on screen to guide user
User programmable time - temp cycle.
Protection from tampering of set parameters: Password incorporated
Self diagnostics software: displays fault condition on screen making repairs easy.
Robust unit:
stainless steel sterilising chamber and M.S. Powder Coated body.
Safety:
power configured in cut-off mode in its natural steady state of rest

 
Specifications:
Construction                        Stainless Steel Chamber with M. S. Powder Coated outer body
Power Rating – Heater  

500 Watts

Control System                     Less than 50 Watts
Operating Voltage   230 Volts +/- 10%, 50 Hz, 1Phase
Control Type                        Micro-computerized control with LCD display.
Protection   Password Protection against un-authorized tampering
Memory   Built – in Power Failure Memory.
Alerts   By Visual indications.
Set Temperature                  

By various keys on keyboard.

Temp Set Range                  

0 to 175 Degree Centigrade

Time Set Range                    0 to 9 Hrs 59 Mins
Display    2 x 16 Liquid Crystal Display   (2 Rows x 16 Charatcers)
Display Indication              

Set/Actual Temp in Deg. C *  Set Time in H:MM *  Process Alerts   *  Process Over

       
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
POWER FAILURE MEMORY – HOW IT WORKS?
Once the “Run” key is pressed, the process starts and micro-controller continuously monitors the process parameters and saves them in internal memory. At Power Failure these process parameters are stored in Memory provided on board. This memory is non-volatile and can be retained for a long period.

On resumption of power, the controller restarts and retrieves the temperature value at power failure and compares it with actual value on power resumption. If the drop in temperature is more than 10% of the value at power failure, then the processor re-starts the process from beginning and if f the drop in temperature is less than 10% of the stored value, then the process resumes from where it stopped at power failure.
This is done automatically.

WHY PASSWORD?

Password is required only to edit process parameters like set temperature time. Password is not required to Run the Process with previously set values.
This facilitates the control of Supervisor or H.O.D over process parameters set values and permits the Junior staff / student to run the process without need of presence to Supervisor / H. O. D.

WHAT IF PASSWORD FORGOTEN?

If the user has forgotten Password, then the default Password can be loaded through Key Switch on the right face of the control panel.

DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE

 
Hydraulic Press

Capacity 3 tons
Perfectly packs the flask after filling acrylic
Exerts uniform pressure throughout the surface
Hydraulic gauge indicates pressure in tons
Ease of operation
Simple release mechanism

 
Specifications:
Construction   M. S. Painted
Flask Mounting Area         

3.5”Dia

Max. Pressure   3 Tons
Pressure Application   By Plunger Up & Down movement
Max. Displacement   1.5” approx
Pressure Release   By Front Release Key
Pressure Display   By Hydraulic Gauge
       
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
 
Model Trimmer

High Speed Heavy Duty Motor
Front Face Operation
Perfect ergonomics for ease of use
Option for Coarse or Fine Grinding Disc

 
Specifications:
Construction  

M. S. Powder Coated

Speed         

2800 RPM

Power   0.5 Hp
Disc Size   9”
Motor Mounting   Elevated for convenient operation
Input Supply   230 V AC, 50 Hz, 1 Phase
       
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
 
Pindex Laser System

Ideal for split model technique
Bright laser light for accurate drill point setting
User adjustable laser positioning system
High speed drill motor
Large platform
Sturdy body

 
Specifications:
Construction  

M. S. Powder Coated

Operating Voltage        

230 Volts +/- 10%, 50 Hz, 1Phase

Motor Type   Miniature Size High Speed
Platform Size  

8” x 6” approx

Vertical Displacement   1” Approx
Laser Light Adjustment   Manual by User
       
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
 
Plaster Dispenser

10 kg capacity
Auto operation at the flick of a switch. No pulling of lever required
Dispensing start / stop controlled by toggle switch
Flexible mounting: wall or table

 
Specifications:
Construction  

M. S. Powder Coated

Size       

13” x 13” x 17” approx

Operating Voltage   230 Volts +/- 10%, 50 Hz, 1Phase
Control Type  

Fully automatic by Toggle Switch

Dispensing Rate   300 Gms per minute minimum
Capacity   10 Kgs
Mounting   Flexible - Wall  or Table Top as desired by user
       
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
 
Pre Heating Furnace

Max temp: 500 deg. C.
Muffle size: 4 x 4x 8”
Digital controller plus indicator
Compact size


 
Specifications:
Construction  

M. S. Powder Coated

Size       

225 x 365 x 420 mm approx

Weight   20 Kg approx
Operating Power  

230 Volts AC +/- 10%, 50 Hz 1 Phase

Power Consumption   1500 Watts
Control Power   Less than 50 Watts
Temp Indication   By LED Display
Temp Control   0 to 500 Deg. C
       
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
 
Pressure Pot - Cold Cure

Indispensable unit for Porosity Free Polymerisation of Self Cure Resin
Time saving. Performs process very fast at the press of a button.
Cost saving. 10 models can be cured at a time.
Stainless steel curing chamber with Safety Valve and Pressure Gauge
Pressure cooker construction for convenient loading and unloading of models.



 
Specifications:
Construction  

Chamber Stainless Steel

Chamber Sizes  

8” (DIA) x 8” (H) Approx

Water Filling   Manual
No. of models accommodated   

Over 10

Curing Cycle   By Pressure Application for upto 9 Mins 59 Secs settable
Safety   Mechanical Safety Valve – Auto Operated
Operating Pressure   2 Bar to be filled manually initially
Pressure Display   Needle type Pressure Gauge
       
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
 
Pressure Pot - Heat Cure

Indispensable unit for Porosity Free Polymerization of Heat Cure Resin in crowns and bridges
Time saving. Performs process very fast at the press of a button.
Micro controller based fully automatic unit
Big screen for display of messages and menu
Cost saving. 10 models can be cured at a time.
Stainless steel curing chamber with Safety Valve and Pressure Gauge
Pressure cooker construction for convenient loading and unloading of models.

 
Specifications:
Construction  

Chamber Stainless Steel

Controller  

M. S. Powder Coated

Chamber Sizes  

8” (DIA) x 8” (H) Approx

Water Filling   Manual
Power Rating – Heater   1000 Watts
Controller   Less than 50 Watts
Operating Voltage   230 Volts +/- 10%, 50 Hz, 1Phase
Display Type   2 x 16 Liquid Crystal Display (2 Lines x 16 characters)
No. of models accommodated   Over 10
Control   Micro Computerized with LCD Display
Process   Automatic
Time Range       0 to 9 Mins 59 Secs Programmable
Time Counting      Downward
Safety   Mechanical Safety Valve – Auto Operated Manual Safety Valve
Operating Pressure   1.5 to 2 Bar to be filled manually initially
Pressure Display   Needle type Pressure Gauge
Screen Display   1) Help Messages, 2) Error Messages, 3) Process Over 
Process End   Auto OFF with Message and release of pressure
       
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
 
Sand Blaster - Recycle

Large blasting chamber with light
Two blasting nozzles :
Hand pencil for micro (250 microns) sand for ceramic work
Fixed nozzle for macro (400 microns) sand for white metal work
Macro blasting with fixed nozzle recycles sand utilizing full abrasive strength.
Micro blasting done with hand held carbide nozzle.
Micro sand is filled in a jar outside chamber. Used sand falls within chamber which is once again recycled by macro blasting thereby allowing maximum utilization of the abrasive strength.
Hand switch to change blasting mode: micro to macro and vice versa.
Provision for connecting dust extractor
Foot Switch operations.
Operating Pressure 3 to 3.5 bars with pressure zone marked on the gauge.
OPTIONAL
Filter module for protection from dust (dust suction).

 
Specifications:
Construction  

M. S. Powder Coated

Sizes  (approx)  

18” x  12” x  24”(H)

Working Pressure  

3 – 3.5 Bar

Max. Connecting Air Pressure   0 – 10 Bars
Power Supply   230 Volts +/- 10%, 50 Hz, 1Phase
Power Consumption   8 / 10 Watts for lighting
Operation   By Foot Switch
Type   Recycling
No. of sand containers   Two :
One jar for use with hand pencil
One chamber for re-cycling mode.
Blasting Nozzles  

Hand Pencil with carbide nozzle for jar
Fixed hardened steel nozzle for re-cycling chamber

Indication  

Pressure Gauge with operating zone marked by color

       
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
 
Suction Lathe

Micro computerised operation and control.
Low noise motorised suction * Low power consumption.
Bottle inside equipment body,
Auto Start / Stop: Suction starts on lifting the tip from holder. Stops on replacing.
Auto Drain: Automatically drains off when bottle full.

 
Specifications:
Construction  

M. S. Powder Coated

Sizes   

400 x 250 x  600(H) MM

Operation  

Auto Start / Stop & Drain

Power Rating   250 Watts
Operating Voltage   230 Volts +/- 10%, 50 Hz, 1Phase
Controller Type   Micro Computeised
       
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
 
Ultrasonic Cleaner
Specially made for dentists with 1.5 ltr tank capacity. Tanks with higher capacities can be made on request.
Fully stainless steel tank enclosed in durable stainless steel water resistant housing
High power balancing circuit with ideally placed vibrators for efficient cleaning
Built – in heater with thermal cut-off and on/off switch to regulate heating
Microprocessor based count down timer programmable for upto 60 mins
Instant Cleaning Power released on start up.
Meshed tray for maximum unobstructed transfer of cleaning power to the jobs to be cleaned
Dimensions designed to optimally accommodate all hand instruments
 
Specifications:
Construction  

Fully Stainless Steel

Standard  

230 x 30 x 65 mm

Custom  

As per design

Standard  

1.5 litre

Custom   Upto 20 Litres based on customer requirement
Input Supply   230 V AC, 50 Hz, 1 Phase
Standard   80 Watts
Custom   Upto 750 Watts as per design
Standard   160 Watts
Custom   Upto 1000 Watts as per design
Cleaning Frequency   30 KHz +/- 10%
Generator   Solid State MOSFET Design
Generator   Solid State MOSFET Design
Timer   60 Mins Programmable
Heater   Provided with Thermostat and switch
Control   Front Panel Key Switches
       
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
 
Vacuum Mixer - Programmable
Micro computerized control with LCD screen for messages and process result and
With Unique
Single Run Mode for trial of new investment / plaster
5 programmes
3 levels in each programme: pre-mix, mix and post-mix time
Fully automatic
Hands free operations
Edit and save / run facility
Vacuum Gauge for Vacuum Display
 
Specifications:
Construction  

2 Parts – Mixer & Vacuum Pump

Weight  

15 Kgs approx for both parts

Operating Voltage  

230 Volts AC, 50 Hz, 1 Phase

Power Requirement  

400 Watts Max

Mounting   Wall
Vacuum   80%
Vacuum Indication   By Needle Gauge
Parameters Programmable   Pre – Mixing, Mixing and Post Mixing Time
Programming Range   0 to 99 Secs Total Time
Programming Method  

By front panel keys

Display  

2x16 LCD (2 Rows, 16 Characters)

Display Indication   Balance Time in all steps
       
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE
 
Vibrator - Heavy Duty
Heavy Duty
Large Rubber Platform Easy to Clean
Vibration absorbing base
Sturdy Construction
 
Specifications:
Construction  

M. S. Powder Coated

Operating Voltage  

230 V AC, 50 – 60 Hz, 1 Phase

Platform  

Large Rubber Platform

       
DESIGN & SPECS SUBJECT TO CHANGE WITHOUT NOTICE